📄 MasterFrame FAQs: How to model various Structural Elements in MasterFrame

MasterFrame FAQs: How to Model Various Structural Elements

⚠️

Under Construction

Here is a technical guide to the most common "How do I model a [X] in MasterFrame?" support queries logged in our support desk, detailing the software mechanics, practical step-by-step inputs, and engineering limitations for each structural scenario.

Concrete Shear Walls or Core Walls

  • Recommended Method (FE Surfaces): Model vertical 2D FE Surfaces connected to the structural frame. This provides true 3D plate flexure and membrane stress contours ((Fy, τxy), allowing reinforcement design in MasterKey Concrete Wall Design.
  • Legacy Method Caution: The older Create > Add Shear Wall 1D frame method (modeling walls as equivalent columns with rigid links) is legacy. Mixing rigid links with FE surfaces introduces artificial stiffness imbalances and should be avoided.
  • Masonry Wall Rule: Do not model masonry walls as physical FE surfaces or structural shells, as linear elastic shell elements act as deep beams rather than unreinforced compression-only elements. Masonry walls should be applied as direct gravity line loads (UDLs) on supporting beams.


Curved Beams, Roofs, Domes, or Spiral Stringers

  • Native Circular Arcs: 1D structural line members can be modeled as true circular arcs using Create > Add Members > Add Curved Member or Create Curved Member from Facets.
  • Non-Circular / Double Curvature: Physical curved members in MasterFrame are strictly limited to planar circular arcs in steel I-sections or RHS. For double-curved members, parabolic arches, or helical/spiral stair stringers, you must approximate the shape using a faceted assembly of short straight line members connected at shallow angles.
  • Buckling Override: For faceted curves, manually group the segments into a Design Group in MasterKey Steel Design and set the effective LTB length (Lcr) to match the total unbraced arc length.


Tapered Beams or Columns

  • Single Haunch Trick: Open Properties > Member Section Materials, select Single Haunch, set the uniform end lengths (Xh1, Xh2) to 0, and set the depth ratio (Dep H/D < 1.0) at the smaller end relative to the parent section. This creates a smooth linear taper without an intermediate flange plate.
  • Limitations: Tapering is supported natively for standard hot-rolled I-sections and Box sections. Tapered T-sections or built-up plate girders with variable flange width must be modeled as a series of short, faceted straight segments with stepped section properties.
  • See also: 📄 Tapered I-Sections


Tension-Only Bracing or Cable Stays

  • Member Attribute: Model the diagonal or cable using a round bar, CHS, or flat section, and assign the Tension Only (UT) attribute under Loads > Member Loading.
  • Solver Mechanics: The non-linear iterative solver deactivates tension-only members whenever a load case induces compressive axial force.
  • Instability Warnings: Avoid connecting two tension-only or pin-ended members end-to-end without lateral/rotational restraint at the intermediate node, as deactivating both members creates an unstable mechanism. For cable sags, subdivide the cable into smaller segments and execute a non-linear P-Delta second-order analysis.


Floor Diaphragm Action without the FE Module

  • Semi-Rigid Stiff Deck: Navigate to Properties > Stiff-Deck Semi-Rigid, define the deck thickness and E-modulus, and pick boundary members.
  • Structural Action: Generates an internal in-plane membrane mesh that transfers horizontal wind and sway loads back to stability cores or bracing frames without adding out-of-plane flexural plate stiffness.
  • Caution: Do not apply a Stiff Deck onto an existing FE surface floor slab, as FE surfaces inherently model diaphragm action, and combining them double-counts membrane stiffness.


Area Loading Panels and Dummy Member Boundaries

  • Dummy Members: Non-structural line elements used to close open boundary loops or delineate different floor loading zones.
  • Intersections & Load Transfer: Dummy members carry zero structural stiffness. Connecting a dummy directly to another dummy creates an unstable node unless supported. Loads applied directly onto dummy members convert into discrete point loads at their end nodes rather than distributing across the FE slab. For slab overhangs, use Area Loading Edge Projections instead of dummy lines.


Torsion on Goal Post Frames or Offset Loads

  • Torque Eccentricity: In Member Loading, insert a Torq ecc. definition before applied loads, specifying the horizontal (ex) or vertical (ey) offset measured from the Shear Centre.
  • Column Base Stability: Pinned column bases with released beam ends leave columns free to spin about their longitudinal axis (\(Y\)-axis). Apply a torsional rotational restraint (θy) in Nodal Static Supports at the base nodes to prevent matrix singularities.


Steel Staircases and Stringers

  • Hybrid Modeling Approach: Model main inclined channel or box section stringers (PFC/RHS) as 1D line elements to capture global axial, flexural, and torsional behavior.
  • FE Treads: Frame individual treads, risers, and landing plates using 4-sided boundary lines and assign thin 2D FE Surfaces to perform dynamic footfall vibration checks.


Cranked Beams or Rafters

  • Straight Segments Required: Model cranked beams as connected straight segments in MasterFrame.
  • Buckling Checks: Matrix analysis cannot concatenate cranked segments into a single physical design member. In MasterKey Steel Design, open the Axial with Moments brief and manually set Lx and Ly to the total unbraced span length across all segments.